Check the wiring on the hi/lo switch, and follow it closely (trace it) to be sure all ends are connected, not corroded, or covered in insects or debris. Hayward should be able to help, http://www.haywardnet.com see for contact info. Air leaks are another source of priming issues. . EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Also check all the wires, from the back of the terminal board, to the stat. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. Could be clogged impeller? Hi James, I would think that could be one of the E-clips used on the bump shaft may have broken off, or an o-ring has slipped off. After connecting the device, the flow led flashes for one minute and turns off. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. Basically it ran normal and then would get loud, and then go back to normal. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). IF the shaft spins freely, and your motor hums and trips the breaker, first check the wiring connections on the incoming wires, nice and tight, and no bare wire touching anything except the terminal connector. Thanks, Jim, Jim, they can be sticky sometimes. For some time now I have been pushing along with my old cell (t-9 model). Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. If I prime the pump and turn it on it runs fine but when I turn it off and let it set for a few minutes you can hear it cheering then the water in the pump evacuates and there appears to be some water coming from the bottom of the pump. bought a SP2610x152s super pool pump 1.5 hp. Weve tried everything. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. All the electrical connections seem tight. There could also be a short in the wiring to the pump, or from the breaker to the switch. PowerFlo LX is not a self-priming pump (Hayward PowerFlo II is self-priming), which means it has trouble lifting water vertically. Pumps need to be fairly air tight, and water tight to avoid drain down when they shut off. The seal was replaced once on one pump and the entire pump has been replaced the other three times. I connected the pump to a nearby receptacle with a heavy duty drop cord and it works fine. If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. Is there a trick to moving it to 115? The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. The filter timer will not turn on at all, even when trying manually but the cleaner does. We are snow birds in AZ and want to drain the system for the summer. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. Work through the list below if your Hayward pool heater is on the fritz. If I wait for a few minutes after that, the pump starts up again at full speed. Still have Drive error, heatsync overheated and day of weekflashing back and forth between the two. After I moved in a year ago. We have a sand filter and no pressure gage. "@type": "ImageObject",
Oh, and prepare yourself, a new motor or pump may be needed soon. If it blows again then I guess youll have to replace the pump body, which is usually about $100-200 cheaper than the cost of the whole pump. Breville Tamper Coffee Kit 54mm, What should I check? This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. If the salt level is below range, add enough salt to achieve a salt level of 3200 ppm. Is this enough to cause it not to prime or is there an issue with the impeller? If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. Would Hayward do anything for me? The pilot lights, but when I try to jump test the gas valve it clicks and snuffs out the pilot light. Hi Patrick, so you have power from the breaker to the timer and to the switch. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Checked circuit breakers inside and out and checked to make sure power is getting to pump. If your cell looks like 4B, follow the instructions below for cleaning your cell. Ill look up the Drain King, is that something like a check valve? The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. Filters, Learn About the hayward pump is 3years old. Replacement of the gasket inside the valve is the fix. I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) If you have a local electric motor shop in town, you could drive your motor over there for testing. are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) I ended up buying a new Hayward pump online however dont want this to happen again. The filter pressure on low should only be a few psi. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
This one is 5 years old. How do I get the lid tight enough? Hi if a 2-speed motor only works on low speed, that is usually a loose wire or hi/lo switch. We cant figure put how to get the pump going they have a circuit box outside its hooked to but it seems its not working. Third, is there a valve closed after the filter, or some other obstruction? The help at the pool store had no idea what could be wrong. Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. Are you using enough DE powder? Frayed wiring inside the plug or socket. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. If thats not it, check the valves on the suction side (skimmer/main drain) to be sure they are not leaking air. Hi Marsha, Ive had this question a lot this year. Or, 2). Do I need to use lube on the gasket, how much sand should be in the filter? Do you have any suggestion for similar pump? Impeller turns from inside basket. We have a c48l2n134b3 pump. If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. Thanks for the help. It was working great up until a week ago. I have a t-15 cell. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. The pump starts up fine and draws water but then it starts clicking as if its shutting off and on. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. The Super Pump comes with all these labels that say it is set up and wired for 230. It could also be something wrong with the motor, something internal with the windings, or shaft, or bearings, causing excess heat. Third, could be a clog in the main drain or skimmer (suction) pipes. Third guess would be that the connections were not tight on the new motor. Anyone have this issue or have any recommendations? Examine your pumps impeller for any obstructions, and replace the capacitor if necessary. Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). Troubleshooting a Salt Chlorinator First, check power. Repair or replace any tripped breakers or blown fuses. Not too bad of a repair, if you want to attempt yourself. To determine the cause of your noisy pump, investigate the following reasons: Theres no need to feel overwhelmed if your Hayward pool pump isnt functioning correctly. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. None of the indicating lights are on. Have a Hayward variable that was replaced last year. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
It probably just needs to dry out, but breakers that trip do need to be fully turned to Off, before they can be turned back On again. With the pump off, remove the basket and reach your hand back into the eye of the impeller. My pool pump just doesnt turn on. Our pump is going through this one-off cycle similar to what others are describing. Maybe does a quarter of a turn. Hi Mike, its hard to say not knowing which control system you use. Ohms reading should be between 0.5 and 1.0 ohms max. At that moment the generation led turns on and turns off after a few seconds. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. The problem that I have is when I try to start the vacuum to clean the pool. It could also be a clogged impeller or clogged filter, or clogged skimmer line. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Replace the seal in the same orientation as you removed it, and reassemble. Outlet works fine. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. Check that they are tight and havent come loose. Fourth, bad capacitor on the motor? Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? Click OK to extend your time for an additional 0 minutes. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? I have cleaned the rubber gasket, made sure the springs touch to no avail. The salt level is 2300 ppm or less and no chlorine is generating. Im really uncertain exactly how to even look for a solution to my problem. Please advise. It actually burned up shortly after my arrival and troubleshooting it. Hi there if you are hearing no noise from the pump at all, shut off power and check the wiring connections at the pump, switch/timer, and breaker, to be sure wires are making good terminal contact.